Open/Close Of Powder Control Lever 2~3 Times, Open ① & ③ Valve Only And Filter Switch "On" & Check Sight Glass ( It Takes About 2 Min )
FILTERING PROCESS Open ②, ④ Valve Only & Filter Switch "On" ( Continuous Use )
DEHYDRATE PROCESS
When Red Light (Red Lamp) Is "On", Filter Switch "Off" And Close All Valves And Open ⑤ Valve Only. Press Dehydrate Button 5~6 Times With 3 Second Interval And Open/Close Of ⑥ Valves And Start Again From Initial Pre-Coat Process.
Size Of Machine : 1860(H) X 1400(W) X 640(D)Mm
Filtering Capacity : 10 Tons/Hour
Electric Consumption : 2Kw
Filtering Powder : 20Kgs/Bag
No Need To Change The Filter The Filter(Filtering Powder) Is Coated And Taken Out Automatically.